 Copyright ©1998-99:
AMKO Systems Inc.
All rights reserved.
|
ALFA LAVAL MAK SAMPLE GAS CONDITIONER
TECHNICAL DATA
Model |
|
MAK 6-Mini |
MAK 6-1 |
MAK 6-2 |
MAK 6-3 |
MAK 2-1EEx |
MAK
2-2EEx |
Number of Gas Paths |
|
1 |
1 |
2 |
3 |
1 |
2 |
Max. sample inlet temperature |
°C |
140-180* |
Max. sample inlet dewpoint |
°C |
80 |
Outlet gas temperature |
°C |
3 |
Outlet gas dewpoint |
°C |
3 |
Ambient temperature |
°C |
5
to 45 |
Specification |
|
EEx d IIc T4 |
Material of Gas Path |
PVDF |
Operating Pressure (absolute) |
bar |
0.5 - 2.5 |
0.5
- 2.5 |
Max. gas flowrate per gas path |
l/h |
125** |
300** |
Max. sample inlet temperature |
°C |
140 |
180 |
Dead space per gas path |
cm3 |
137 |
137 |
Pressure drop per gas path |
bar |
0.015 |
0.025 |
Material of Gas Path |
Glass |
Operating Pressure (absolute) |
bar |
0.5 - 2.5 |
0.5 - 2.5 |
Max. gas flowrate per gas path |
l/h |
150** |
300** |
Max. sample inlet temperature |
°C |
180 |
140 |
Dead space per gas path |
cm3 |
137 |
137 |
Pressure drop per gas path |
bar |
0.018 |
0.025 |
Material of Gas Path |
Stainless steel, 1.4571 |
Operating Pressure (absolute) |
bar |
0.5-100 |
0.5 - 100 |
Max. gas flowrate per gas path |
l/h |
150** |
500** |
Max. sample inlet temperature |
°C |
180 |
180 |
Dead space per gas path |
cm3 |
137 |
137 |
Pressure drop per gas path |
bar |
0.018 |
0.047 |
Dimensions |
Height |
mm |
250 |
290 |
290 |
350 |
Width |
mm |
300 |
360 |
440 |
470 |
Depth |
mm |
240 |
335 |
360 |
430 |
Weight |
kg |
13 |
19 |
21 |
25 |
56 |
58 |
Electrical Data |
Power supply |
|
230V, 50Hz |
230V, 50Hz |
230V, 50Hz |
230V, 50Hz |
Power consumption |
|
180W, 2.0A |
300W, 2.0A |
350W, 2.4A |
370W, 2.2A |
Options: |
Power supply |
|
230V, 60Hz |
230V, 60Hz |
230V, 60Hz |
230V, 60Hz |
Power consumption |
|
215W, 1.3A |
300W, 2.0A |
350W, 2.4A |
370W, 2.2A |
Power supply |
|
115V, 50/60Hz |
115V,
50/60Hz |
115V, 50/60Hz |
115V,
50/60Hz |
Power consumption |
|
115W, 1.4A |
250W, 2.4A |
300W, 2.8A |
370W, 4.0A |
|