GM 950 INSTANTANEOUS CO SENSOR SYSTEM

iso9001.jpg (10454 bytes)gm950.jpg (16107 bytes)
Measurement of rapid CO concentration peaks.

Due to its low response times, the GM950 can record CO peaks even at high concentrations and measuring value dynamics. Dust concentrations of up to 200 g/m3 are also not a problem.

Application:

Cement industry for explosion protection in electrostatic filters

Advantages:

Representative measuring values thanks to redundant sensors
Direct CO measurement
Easy to install, start up and maintain
Measuring values can be checked and calibrated locally using reference gases
Short response times <2s (typically 1s)

Technical Specifications

System components 2 in-situ CO sensors, sampling probe, analysis cabinet, evaluation unit
Measurment principle Automatically calibrated voltage probes (ZrO2)
Measurementvariable/
Measurement range
CO: 0.1 ... 5 %vol.
Interfaces RS 232, RS 422/485
Enclosre rating Analysis cabinet IP 54, evaluation unit IP 65
Test function Automatic self-test