CLD 70 S
Chemiluminescence NOX Analyzer
The CLD 70 S nitrogen oxide analyzer is the ideal
instrument for stack testing. It is designed for NOX measurements and is
particularly suitable for routine monitoring. With four user-defined measuring ranges up
to 5000 ppm, this analyzer is ready to meet your future requirements.
User Servicable
The instrument has a modular construction
and consequently is very easy to maintain. The reaction chamber can be removed very
quickly for cleaning or replacement and the electronics panel can be folded out for ease
of access.
Trouble-free operation.
The CLD 70 S can be operated with the built-in
keypad or optionally via a PC. Using very simple commands, the user has numerous options
for modifying the test procedure. Consequently the time required for mastering machine
operation is minimal.
Applications:
 |
Stack testing |
 |
Gas turbine installations |
 |
Boiler and burner operations |
 |
Incinerator control |
 |
Power stations |
 |
Metal foundries |
The CLD 70 S nitrogen oxide analyzer offers
valuable service in any situation where the continuous monitoring of limiting values or
quality inspection is required. This rugged analyzer is designed to produce dependable and
accurate results, yet be easy to maintain. The vacuum pump is oil free and only requires
maintenance every twelve months.
Technical
Specifications:
| Measuring
ranges: |
0-5000 ppm; four freely
selectable ranges |
| Minimum
detectable concentration: |
0.2 ppm |
| Noise at zero
point (1 sigma): |
0.1 ppm |
| Zero drift: |
0.2 ppm |
| Linearity (in
range): |
± 1% of full scale |
| Lagtime: |
< 1 sec |
| Rise time
(0-90%): |
< 1 sec |
| Temperature
range: |
50-104 °F (10 - 40 °C) |
| Humidity
tolerance: |
5-95% rel. h (non-condensing,
ambient air and sample gas) |
| Quenching: |
for H2O: <
0.4%/vol.-% H2O with gas cooler |
| for CO2: <
0.4%/vol.-% CO2 |
| Sample flow
rate: |
0.1 l/min |
| Dry air use
(for O3 generator): |
0.45 l/min |
| Power required:
|
500 VA (incl. membrane pump and
ozone scrubber) |
| Supply voltage:
|
115 V/60 Hz, 230 V/50 Hz (± 10%) |
| Interface: |
RS 232 |
| Analog output: |
selectable 1 V/10 V into 500k
minimum, 20 mA into 600 maximum (isolated) |
| Trigger signal
output: |
for control of external
calibration device |
| Weight: |
55 lbs (25 kg) |
| Dimensions: |
height: 5 1/4"; 3 HU (133
mm), with feet 6 1/4" (158 mm) |
| width: 19" (483 mm) |
| depth: 16 15/16" (430 mm) |
| Delivery
includes: |
Analyzer CLD 70 S, membrane
vacuum pump, ozone scrubber, analog signal cable, tubing, manual |
|