RiiSearch CEMSpec 4.0

The Most Advanced Data Acquisition
System For Continuous Emission Monitoring
 |
clean, uncluttered presentation
of measurements |
 |
an intuitive Windows interface
allows the user to quickly and easily operate the system without formal training |
 |
powerful reporting system
combining text and graphics with table of contents indexing |
 |
next generation product based on
ten years experience delivering data acquisition systems to the North American market |
 |
operates under Microsoft Windows
XP / 2000 |
The Graphical Interface
 |
trends are grouped according to
user configuration; these groupings can be changed at any time using the group
configuration window |
 |
automatic scrolling of real-time
trends ensure the most recent data is always displayed |
 |
Y-axis parameters for each trend
are adjustable through the system configuration |
 |
up to 6 different averages can
be calculated and displayed with user defined averaging intervals |
 |
ability to trend historical data
for any or all channels, including scrolling of historical data |
 |
supports trending of calibration
drift over a user defined time period |
Report Customization
 |
providing an index of templates
for quick access to predefined report templates as well as custom reports |
 |
a report design wizard that
assists in the generation of custom reports |
 |
integrating graphical as well as
tabular reporting |
 |
exporting filters allow the
transfer of data to other applications including Adobe Acrobat and Rich Text Format, a
preview window, or directly to an attached printer |
 |
standardized reports that are
generated using parameters defined by the user; these include general data values reports
of averages, calibration data, alarms and events |
Alarms and Events
 |
all Alarms are sent to the
Alarms panel for acknowledgement |
 |
alarms are acknowledged using
the Alarms display and with defined reason codes |
 |
events are handled in a similar
manner as Alarms |
System Configuration
 |
supports up to 32 separate data
channels as well as 128 status bits |
 |
configuration allows the user to
set various system parameters and display settings |
 |
automated functions such as
back-up of data files, generation of reports, etc. can be configured by the user to
execute at specific dates and times |
Data Storage and Back-Up
 |
all averaged data values,
calibration data, sensor data, alarms and events are stored in a Microsoft Access
compatible database using a relational database design, allowing for greater flexibility
and speed |
 |
built-in support for back-up of
data files to a Syquest Sparq drive or other back-up medium |
Analyzer Interfaces
 |
communication directly with
smart analyzers via serial communications allows for data collection, display and storage
without an intermediate device |
 |
current implementations include:
SICK|Maihak MCS 100 and MCS 100E; Modbus based PLCs; Allen Bradley PLCs |
 |
custom interfaces are also
available |
 |
interface to plant control
systems (i.e. DCS) via Ethernet / Modbus / Profibus |
Remote Support
 |
remote support is provided using
Symantecs pcAnywhere software |
System Requirements
 |
Intel Pentium 166 or better |
 |
64MB RAM, 2GB hard drive, CD-ROM |
 |
800x600 resolution or higher
video display |
 |
Windows XP / 2000 |
 |
US Robotics 56.6 kbaud modem |
 |
Symantecs pcAnywhere 8.0
or newer |
 |